Item # S-400W
·Input: 220VAC
·Protections: Short circuit/Over load/Over voltage
·Built-in cooling DC fan
·Dimension: 215*115*50mm (L*W*H)
Model |
S-400-5 |
S-400-12 |
S-400-15 |
S-400-24 |
S-400-36 |
S-400-48 | |
Output |
DC voltage |
5V |
12V |
15V |
24V |
36V |
48V |
Voltage tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% | |
Rated current |
60A |
33A |
27A |
16.5A |
11A |
8.3A | |
Current range |
0~60A |
0~33A |
0~27A |
0~16.5A |
0~11A |
0~8.3A | |
Rated power |
300W |
396W |
405W |
396W |
396W |
398.4W | |
Ripple&noise |
100mvp-p |
150mvp-p |
150mvp-p |
150mvp-p |
180mvp-p |
200mvp-p | |
DCvoltage ADJ.range |
-9%~+10% |
±10% |
±10% |
±10% |
±10% |
±10% | |
Input |
Voltage range |
90~132VAC/180~264VAC(selected by switch),255~373VDC | |||||
frequency |
47~63HZ | ||||||
AC current |
7.5A/115VAC,4.5A/230VAC | ||||||
efficiency |
78% |
80% |
80% |
82% |
82% |
83% | |
Inrush current |
Cold start current 30A/115VAC,60A/230VAC | ||||||
Leakage current |
< 3.5mA/240VAC | ||||||
Protection |
overload |
Rated output power105%~135% start over load protection | |||||
protection type :rated current limit ,auto-recovery after fault condition is removed | |||||||
Over voltage |
6.8~8.2V |
15.6~17.8V |
18.6~20.8V |
30.6~33.2V |
42.6~44.2V |
54.8~56.6V | |
Protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
Over temperature |
≥55℃fan on,≤50℃fan off,≥85℃ start over temperature protection | ||||||
Protection mode:cutoff output,auto-recovery after temperature become normal | |||||||
Environment |
Working temp,humidity |
-10℃~+60℃,20%~90%RH | |||||
Storagetemp,humidity |
-20℃~+85℃,10%~95%RH non-condensing | ||||||
Withstand vibration |
10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | ||||||
Safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC | ||||||
Fitstandard |
Safety standard |
Fit UL1012 | |||||
EMC standard |
EN55022,CLASSA | ||||||
Others |
Dimension |
215*115*50mm (L*W*H) | |||||
Weight/packing |
1.0kg/24pcs/25kg/0.049 m³/1.72CUFT | ||||||
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |