English
  • English
  • Deutsch
  • Português
  • Español
  • Français
  • italiano
  • 日本語
  • 한국의
  • العربية
  • Pусский
  • Thermometer & Hygrometer
    • In&Out Thermometer
    • Indoor Thermo-Hygrometer
    • In & Out Thermo-Hygrometer
    • Food Thermometer
    • Infrared Thermometer
    • Analog Thermo-Hygrometer
    • Sauna Meter
    • PH Meter
    • TDS Meter
    • EC Meter
  • Instruments
    • Temperature Controller
    • Humidity Controller
    • Temperature Transmitter
    • Hour Meter & Counter
    • Time Relay
    • Solid State Relay
    • Ampere&Volt Meter
    • Thermocouple/RTD
    • Thermostat
  • Switching Power Supply
    • Single Output
    • Mini Power Supply
    • Din Rail Power Supply
    • Led Waterproof Power Supply
    • Pfc Power Supply
    • Constant Current
    • Dual Output
    • Triple Output
    • Quad Output
    • Open Frame
    • Rainproof Power Supply
  • Time Switches
    • Digital Timers
    • Mechanical Timers
    • Plug in Timers
    • Energy Savers
    • Enclosures
  • Home
  • About Us
  • News & Events
  • Support
  • Feedback
  • Contact Us
  • Sitemaps
Browse:Economical series
  • Temperature Controller
    • Economical series
    • CD series
    • SG series
    • E5 series
    • XY series
    • JTC series
    • Other series
  • Humidity Controller
  • Temperature Transmitter
  • Hour Meter & Counter
  • Time Relay
  • Solid State Relay
    • Singh Phase SSR
    • Three Phase SSR
    • Heat Sink
  • Ampere&Volt Meter
  • Thermocouple/RTD
  • Thermostat
You are here: Home » Products » Temperature Controller » Economical series

Economical Temperature Controller REX series

 

General Introduction:

REX series PID Temperature Controller are the economical series. It adopts special microcomputer adjusting meter that employs switching power and surface mount technology (SMT), therefore, the controller is quite smart and reliable. Its special functions like auto diagnosing, auto setting and intelligent control. It can be used widely in the display and control of the parameter of the temperature, pressure, flow, and liquid level.

 

Product Features:

• Input: Universal input, support 10 different types of  thermocouples and RTD inputs by customers selected at panels.

• Usage in heating control or cooling control

• Display temperature in Celsius (°C)

• Control precision: +/- 0.5%

• Control mode: PID, ON/OFF

• Control Output:  Relay contact (3A @ 240 VAC),   Voltage impulse output  for external SSR,  Current 0-20mA, 4~20 mA,  Voltage 0-5V,0-10VDC

• Alarm: AL1 or AL2,  7 kinds of alarm mode: high/low/high deviation/low deviation/interval/out of interval/breakage alarm.

• Power Supply: 100~240V AC 50/60Hz,  DC24V, or other voltage according your order.

 

Model Description and Model Selection:

            Outline Size                              Panel Cutout

 

 

Model 

A

B

C

D

E

F

G

H

C100

48

48

10

100

45

45

80

80

C410

96

48

10

100

92

45

116

80

C400

48

96

10

100

45

92

80

116

C700

72

72

10

100

68

68

96

96

C900

96

96

10

100

92

92

116

116

 

REX – C□ 0 0-□ □ □ - □□ * □□

                ①         ② ③ ④     ⑤ ⑥   ⑦ ⑧

1 Outline Size(see the abvoe form)

2 Control Type

   F:PID operation and auto calculation(Reverse operation)

   D:PID operation and auto calculation(Forward operation)

3.Input Type:  refer to input range table

4.Range Code: refer to input range table

5.First Control Output (OUT1) (Heating side)

   M: Relay Contact output                         8: Current output( DC 4~20mA)

   V: Voltage impulse output for SSR       T: Hydration driving output

6.Second Control Output (OUT2) (Cooling side)

   Null: when control operation is F or D

   M: Relay Contact output                         8: Current output( DC 4~20mA)

   V: Voltage impulse output for SSR       T: Hydration driving output

7. First Alarm(ALM1)     8.Second Alarm(ALM2)

    N: no alarm               A: Upper-Limit bias alarm      

    B: Lower-Limit bias alarm  C: Upper/Lower Limit bias alarm  

    D: Alarm in area          

    E: Standby upper-limit bias alarm attached

    F: Standby lower-limit bias alarm attached

    G: Standby upper/lower limit bias alarm attached

    H: Upper-Limit input value alarm 

    J: Lower-limit input value alarm

    K: Standby upper-limit input value alarm attached

    L: Standby lower-limit input value alarm attached

 

The Input Range Table:

 

Code

Input Range

Code

Input Range

Code

Input Range

Themocouple Input(TC)

K

K01

0-200°C

K02

0-400°C

K03

0-600°C

K04

0-800°C

K05

0-1000°C

K06

0-1200°C

K07

0-137 2°C

K13

0-100°C

K14

0-300°C

 

J

J01

0-200°C

J02

0-400°C

J03

0-600°C

J04

0-800°C

J05

0-1000°C

J06

0-1200°C

 

R  *1

R01

0-1600°C

R02

0-1769°C

R04

0-1350°C

S  *1

S01

0-1600°C

S02

0-1769°C

 

 

B  *1

B01

400-1800°C

B02

0-1769°C

 

 

E

E01

0-800°C

E02

0-1000°C

 

 

N

N01

0-1200°C

N02

0-1300°C

 

 

 

T  *2

T01

0-350°C

T02

-199.9-100.0°C

T03

-199.9-200.0°C

T04

-199.9-400.0°C

 

 

 

 

 

RTD Input

PT100

D01

-199.9-649.0°C

D02

-199.9-200.0°C

D03

-199.9-50.0°C

D04

-100-100.0°C

D05

-100-200.0°C

D06

0.0-50.0°C

D07

0.0-100.0°C

D08

0.0-200.0°C

D09

0.0-300.0°C

D10

0.0-500°C

 

 

 

 

 

JPT100

P01

-199.9-649.0°C

P02

-199.9-200.0°C

P03

-199.9-50.0°C

P04

-100-100.0°C

P05

-100-200.0°C

P06

0.0-50.0°C

P07

0.0-100.0°C

P08

0.0-200.0°C

P09

0.0-300.0°C

P10

0.0-500°C

 

 

 

 

 

Voltage Input

0-5V

401

0.0-100°C

 

 

 

 

1-5V

601

0.0-100°C

 

 

 

 

Current Input

0-20mA

701

0.0-100°C

 

 

 

 

4-20mA

801

0.0-100°C

 

 

 

 

Note: *1 The accuracy can not be guaranteed in 0-399°C

           *2  The accuracy can not be guaranteed in -199.9-100°C

 

REX-C100
REX-C100
Item#REX-C100
REX-C700
REX-C700
Item#REX-C700
REX-C400
REX-C400
Item#REX-C400
REX-C410
REX-C410
Item#REX-C410
REX-C900
REX-C900
Item#REX-C900
REX-C800
REX-C800
Item#REX-C800

Copyright © 2012 Yueqing Xinyang Technology Co., Ltd. Technology:Otree

Home | About Us | Products | News & Events  | Support | Contact Us